LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2002 >> Sebring LXi, 2D Coupe, Standard >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Remote Keyless Entry System - Coupe >> Programming >> Enabling/Disabling Hazard ANSWERBACK Function >> Notes

Enabling/Disabling Hazard ANSWERBACK Function: Notes

NOTE: This feature will flash hazard lights when doors are locked and/or unlocked using Remote Keyless Entry (RKE) transmitter LOCK/UNLOCK buttons.
NOTE: The hazard answerback function can be enabled or disabled by one of the 2 following procedures.
  • When the transmitter is used after connecting Scan Tool (MB991502) to the data link connector.
  • By grounding data link connector terminal.
  1. Enter the hazard answerback customize mode by observing one of the following steps. If the ETACS-ECU enters the customize mode, its tone alarm will sound once.
    • Connect Scan Tool (MB991502) to the data link connector terminal No. 1.
    • Turn the ignition switch to LOCK (OFF) position.
    • Close the driver's side door.
    • Leave the windshield washer switch on for at least 10 seconds. Then the ETACS-ECU tone alarm will sound once.
  2. If the transmitter LOCK switch is pushed consecutively twice (within 2 seconds), the ETACS-ECU tone alarm will sound, indicating that the hazard answerback function can be enabled or disabled when the doors are locked.
    • Enable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound once.
    • Disable the hazard answerback function when the doors are locked: The ETACS-ECU tone alarm will sound twice.
  3. If the transmitter UNLOCK switch is pushed consecutively twice (within 2 seconds), the ETACS-ECU tone alarm will sound, indicating that the hazard answerback function can be enabled or disabled when the doors are unlocked.
    • Enable the hazard answerback function when the doors are unlocked: The ETACS-ECU tone alarm will sound once.
    • Disable the hazard answerback function when the doors are unlocked: The ETACS-ECU tone alarm will sound twice.
  4. Exit the hazard answerback customize mode by observing one of the following steps.
    • Disconnect Scan Tool (MB991502) from the data link connector, or disconnect data link connector terminal No. 1 from the ground.
    • Turn the ignition switch to position other than LOCK (OFF), or remove the ignition key.
    • Open the driver's side door.

    If any operation is not done for at least 3 minutes after the ETACS-ECU has entered the customize mode, the hazard answerback customize mode will be canceled automatically.