LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2013 >> Sienna XLE, AWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System (2GR-FE) (Service Specifications) >> 2GR-FE Battery / Charging >> Service Data >> Service Data

Service Data

Battery Standard specific gravity: 1.25 to 1.29 at 20°C (68°F)
Standard voltage 12.6 to 12.8 V at 20°C (68°F)
Charging circuit without load Standard current 10 A or less
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard current 30 A or more
Generator brush holder assembly brush exposed length Standard exposed length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length 4.5mm (0.177 in.)
Generator rotor assembly resistance Slip rings 1.5 to 1.9 Ω at 20°C (68°F)
Slip ring - Rotor 10 MΩ or higher
Generator rotor assembly slip ring diameter Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14 mm (0.551 in.)