LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> Highlander Base, AWD >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications - Except Hybrid >> 2GR-FE Starting System >> Service Data

Service Data

SERVICE DATA SPECIFICATION

Starter assembly Standard current: 90 A or less at 11.5 V
Repair service starter kit Standard resistance
Terminal 50 - Terminal C: Below 1 Ω
Terminal 50 - Switch body: Below 2 Ω
Starter armature assembly Standard resistance
Segment - Segment: Below 1 Ω
Segment - Coil core: 10 kΩ or higher
Standard length: 3.1 to 3.8 mm (0.122 to 0.150 in.)
Starter commutator end frame Standard length: 4.0 to 9.0 mm (0:158 to 0.354 in.)
Standard resistance
Positive (+) - Negative (-): 10 kΩ or higher
Snap ring Maximum length: 5.0 mm (0.197 in.)
Starter relay 3 - 5: 10 MΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
Starter cut relay 3 - 5: 10 MΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
ACC relay 3 - 5: 10 kΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
No.1 ignition relay 3 - 5: 10 kΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
No.2 ignition relay 3 - 5: 10 kΩ or higher
3 - 5: Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
Ignition switch LOCK: Between all terminals 10 kΩ or higher
ACC: 4 (AM1) - 2 (ACC) Below 1 Ω
ON: 4 (AM1) - 2 (ACC) Below 1 Ω
ON: 4 (AM1) - 1 (IG1) Below 1 Ω
ON: 5 (AM2) - 6 (IG2) Below 1 Ω
START: 4 (AM1) - 1 (IG1) Below 1 Ω
START: 4 (AM1) - 3 (ST1) Below 1 Ω
START: 5 (AM2) - 6 (IG2) Below 1 Ω
START: 5 (AM2) - 7 (ST2) Below 1 Ω
Engine switch 7 (SS1) - 5 (GND) / 2 (SS2) - 5 (GND)
Specified resistance
Not pushed: 10 kΩ or higher
Pushed: 15 Ω
Standard condition: Illuminates
Measurement condition
Battery positive 11 (SWIL) - Battery negative 4 (COM) or 5 (GND)
Battery positive 12 (INDS) - Battery negative 4 (COM) or 5 (GND)
Battery positive 13 (INDW) - Battery negative 4 (COM) or 5 (GND)