LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 1996 >> Swift Standard >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Overhaul - ECC 3-Speed >> Testing >> Time Lag Test >> Time Lag Test Results

Time Lag Test Results

If "P" to "R" time lag is longer than specified, line pressure is too low, direct clutch is worn and/or 1st and reverse brake is worn. If "R" to "D" time lag is longer than specified, line pressure is too low, forward clutch is worn and/or one-way clutch is faulty.