Method With Timing Light
WARNING: This page is about a different variant/trim than selected.
- Before checking the ignition timing, check the following item:
- Check the air cleaner element is free from clogging, spark plugs are in good condition, and hoses are connected properly.
- Check the malfunction indicator light does not illuminate.
- Warm up the engine.
- Stop the engine, and turn the ignition switch to OFF.
- Remove the air cleaner case. Refer to REMOVAL , Air Cleaner Case.
- Connect the timing light to the power wire of #1 ignition coil.
- Install the air cleaner case. Refer to INSTALLATION , Air Cleaner Case.
- Start the engine, aim the timing light to the crank pulley, and check the ignition timing by the crank pulley indicator.
Ignition timing [BTDC/RPM]:
15°±8°/650