Check Hazard Light Operation
DIAGNOSIS PROCEDURE CHART
| Step |
Check |
Yes |
No |
1 CHECK HAZARD LIGHT OPERATION
. Make sure the hazard light blinks when hazard switch is turned to ON. |
Does the hazard light blink? |
Go to step 2
. |
Check the hazard light circuit. |
2 CHECK OUTPUT TO HAZARD LIGHT
.
- Turn the ignition switch to OFF.
- Disconnect the key warning switch harness connector.
- Prepare the Subaru Select Monitor kit.
- Turn the ignition switch to ON (engine OFF), and run the "PC application for Subaru Select Monitor".
- On the "System Selection Menu", select {Integ. unit mode}.
- Select {ECM customizing}.
- Check {Hazard answer-back setup}, and then switch to ON setting if necessary.
- Select the {Current Data Display & Save}.
- Remove the key from ignition switch.
- When operating the LOCK/UNLOCK button of the transmitter, check the hazard output signal of the body integrated unit.
|
Is output signal present when operating the transmitter LOCK/UNLOCK button? |
Go to step 3
. |
Check the body integrated unit. Refer to
BASIC DIAGNOSTIC PROCEDURE
. |
3 CHECK CIRCUIT OF HAZARD LIGHT
.
- Disconnect the harness connector of body integrated unit.
- Disconnect the turn signal and hazard unit harness connector.
- Measure the resistance between harness connector terminals.
Connector & terminal (B281) No. 22 - (B32) No. 8: |
Is the resistance less than 10 Ω? |
Check the body integrated unit. Refer to
BASIC DIAGNOSTIC PROCEDURE
. |
Repair or replace the harness. |