Component Function Check
- CHECK FUNCTION
Check encoder ("ENCODER A", "ENCODER B") in Data Monitor mode.
Monitor item Condition Status ENCODER A Back door Moving Change HI or LO Stop No change HI or LO ENCODER B Back door Moving Change HI or LO Stop No change HI or LO Is the inspection result normal?
YES: Encoder is OK.
NO: Refer to "DIAGNOSIS PROCEDURE ".