ELECTRIC SHIFT CONTROL MODULE TERMINALS REFERENCE CHART

Terminal (Wire color) Item Condition Value (Approx.)
+ - Signal name Input/Output
1 (L) Ground MOTOR COIL A U-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
2 (W) Ground MOTOR COIL A V-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
3 (B) Ground GND - Always 0 V
4 (B) Ground GND - Always 0 V
5 (V) Ground MOTOR COIL A WPHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
6 (B) Ground GND (MOTOR) - Always 0 V
7 (W) Ground MAIN POWER SUPPLY 1 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
8 (R) Ground BACK UP POWER SUPPLY Input Always 9 - 16 V
9 (BR) Ground POWER SW 1 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
10 (Y) Ground ANGLE SENSOR 1 POWER SUPPLY - Power switch ON   5 V
11 (L) Ground ANGLE SENSOR 1 SIGNAL Input READY Selector lever is P position (Manual plate: P position) 1.42 - 2.20 V
Other than the above (Manual plate: Not P position) 2.85 - 3.56 V
12 (W) Ground P POSITION SIGNAL Output READY Selector lever is P position 0 V
Other than the above 9 - 16 V
13 (R) Ground P/N POSITION SIGNAL Output READY Selector lever is P and N positions 9 - 16 V
Other than the above 0 V
14 (P) Ground STOP LAMP SWITCH Input Power switch ON Brake pedal is depressed 9 - 16 V
Brake pedal is released 0 V
15 (LG) Ground ENCODER SIGNAL B Input Parking actuator is operated  
G07084439Courtesy of NISSAN MOTOR CO., U.S.A.
16 (R) Ground ENCODER POWER SUPPLY - Power switch ON   5 V
17 (V) Ground ELECTRIC SHIFT POWER SUPPLY RELAY Output Power switch ON   0 V
Power switch OFF   9 - 16 V
18 (SB) Ground PARKING ACTUATOR RELAY A - Power switch ON   0 V
Power switch OFF   9 - 16 V
19 (P) Ground ELECTRIC SHIFT SENSOR POWER SUPPLY 1 - Power switch ON   5 V
20 (LG) Ground WAKE UP SIGNAL Input Power switch ON   9 - 16 V
21 (GR) Ground ANGLE SENSOR 1 GND - Always 0 V
22 (L) Ground N POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is N position 1 V or less
Other than the above 9 - 16 V
23 (G) Ground ENCODER GND - Always 0 V
24 (W) Ground ENCODER SIGNAL A Input Parking actuator is operated
G07084440Courtesy of NISSAN MOTOR CO., U.S.A.
25 (B) Ground GND (MOTOR) - Always 0 V
26 (R) Ground D POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is D position 1 V or less
Other than the above 9 - 16 V
27 (BR) Ground MOTOR COIL B U-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
28 (GR) Ground MOTOR COIL B V-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
29 (R) Ground MOTOR COIL B W-PHASE Output Power switch ON   9 - 16 V
Power switch OFF   0 V
30 (Y) Ground R POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is R position 1 V or less
Other than the above 9 - 16 V
31 (L) Ground EV SYSTEM CAN-H Input/Output - -
32 (G) Ground EV SYSTEM CAN-L Input/Output - -
33 (GR) Ground PARKING ACTUATOR RELAY B - Power switch ON   0 V
Power switch OFF   9 - 16 V
34 (B) Ground ELECTRIC SHIFT SENSOR NO. 1 Input READY Selector lever is held in R position 0 V
Other than the above 5 V
35 (L) Ground ELECTRIC SHIFT SENSOR NO. 2 Input READY Selector lever is held in R and N positions 0 V
Other than the above 5 V
36 (R) Ground ELECTRIC SHIFT SENSOR NO. 3 Input READY Selector lever is held in H (Home) and N positions 0 V
Other than the above 5 V
37 (Y) Ground ELECTRIC SHIFT SENSOR NO. 4 Input READY Selector lever is held in N and D position 0 V
Other than the above 5 V
38 (B) Ground P POSITION OUTPUT (SELECTOR INDICATOR) Output READY Selector lever is P position 1 V or less
Other than the above 9 - 16 V
39 (LG) Ground ANGLE SENSOR 2 POWER SUPPLY - Power switch ON 5 V
40 (P) Ground ANGLE SENSOR 2 SIGNAL Input READY Selector lever is P position (Manual plate: P position) 1.42 - 2.20 V
Other than the above (Manual plate: Not P position) 2.85 - 3.56 V
41 (BR) Ground ELECTRIC SHIFT SENSOR GND 1 - Always 0 V
42 (G) Ground POWER SW 2 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
43 (W) Ground MAIN POWER SUPPLY 2 Input Power switch ON   9 - 16 V
Power switch OFF   0 V
44 (W) Ground ELECTRIC SHIFT SENSOR NO. 5 Input READY Selector lever is held in D position 0 V
Other than the above 5 V
45 (G) Ground ELECTRIC SHIFT SENSOR NO. 6 Input READY Selector lever in H (Home) position 0 V
Other than the above 5 V
46 (R) Ground P POSITION SWITCH NO. 7 Input READY P position switch is pushed 5 V
Other than the above 0 V
47 (B) Ground P POSITION SWITCH NO. 8 Input READY P position switch is pushed 0 V
Other than the above 5 V
48 (SB) Ground ELECTRIC SHIFT SENSOR POWER SUPPLY 2 - Power switch ON   5 V
49 (G) Ground ANGLE SENSOR 2 GND - Always 0 V
50 (LG) Ground ELECTRIC SHIFT SENSOR GND 2 - Always 0 V