Hazard Reminder Check
- CHECK HAZARD WARNING LAMP
Does hazard warning lamp flash with hazard switch?
YES or NO
YES: GO TO 2.
NO: Check hazard warning lamp circuit. Refer to "TURN SIGNAL AND HAZARD WARNING LAMPS ".
- CHECK HAZARD REMINDER OPERATION
- Remove key from ignition key cylinder.
- Check voltage between smart entrance control unit harness connector and ground.
VOLTAGE REFERENCEConnector Terminals (Wire color) Condition of key fob Voltage [V] (Approx.) (+) (-) M91 47 (G/B) Ground Lock button is pressed. 0→Battery voltage→0 Unlock button is pressed. 0→Battery voltage→0→Battery voltage→0 48 (G/Y) Lock button is pressed. 0→Battery voltage→0 Unlock button is pressed. 0→Battery voltage→0→Battery voltage→0 Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: Check harness for open or short between smart entrance control unit and hazard switch.
NG: Replace smart entrance control unit.