Injection Pump Controller System: Controller
- With positive battery lead connected to assembly terminal 13, and negative lead to terminal 14, the controller motor should run. See Fig 1 .
- Remove positive lead from terminal 13. With negative lead still at terminal 14, connect terminals 12 and 13 to each other with an insulated jumper wire. See Fig 2 .Connect positive lead to terminal 8.
- Connect a second positive lead to terminal 9 and check control lever. It should be in the "Start" position. See Figure . Move second lead to terminal 10. Lever should be in the "Stop" position.
- Move lead to terminal 11 and lever should move to "Drive" position. If not, assembly should be replaced.