LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2025 >> Outlander PHEV ES >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transaxle >> Electrical Parking Driver Unit >> Diagnosis >> Diagnostic Function >> Freeze Frame Data Check

Freeze Frame Data Check

By using the scan tool (M.U.T.-III SE), the freeze frame data can be checked.

When detecting fault and setting the diagnostic trouble code, the ECU connected to CAN bus line obtains the data when the diagnostic trouble code is determined, and then stores the ECU status of that time. By analyzing each data using the scan tool (M.U.T.-III SE), troubleshooting can be carried out efficiently. The displayed items are as the table below.

Check a freeze frame data before removing the 12V battery.

DISPLAY ITEM LIST

Item No. Scan tool (M.U.T.-III SE) display Unit or value
10 ODO/TRIP METER km/mile
20 DTC count The number of times is displayed.
30 Motor Relay High Failure Normal/Failure
40 Motor High Failure Normal/Failure
50 Motor Drive Circuit Low Failure Normal/Failure
60 Encoder Failure Normal/Failure
70 Continuous Energization Failure Normal/Failure
80 Shifting Failure Normal/Failure
90 Current Limitation Failure Normal/Failure
100 Low Voltage Failure Normal/Failure
110 Overcurrent Failure Normal/Failure
120 CAN Bus-off Normal/Failure
130 Lost Communication with PHEV-ECU Normal/Failure
140 CAN Invalid Failure Normal/Failure
150 CAN Self-Diag Failure Normal/Failure
160 LIN Lost Communication with PHEV-ECU Normal/Failure
170 Microcomputer Error (ROM) Normal/Failure
180 Microcomputer Error (RAM) Normal/Failure
190 Microcomputer Error (FLOW) Normal/Failure
200 Microcomputer Error (INST) Normal/Failure
210 ASIC Error Normal/Failure
220 Data Flash Error Normal/Failure
230 Power Supply Holding Function Error Normal/Failure
240 Relay Output Status ON/OFF
250 +B Voltage V
260 U-Phase Terminal Monitoring Voltage V
270 V-Phase Terminal Monitoring Voltage V
280 W-Phase Terminal Monitoring Voltage V
290 U-Phase Output Terminal Status ON/OFF
300 V-Phase Output Terminal Status ON/OFF
310 W-Phase Output Terminal Status ON/OFF
320 Common Current A
330 IG Status ON/OFF
340 Vehicle Request Shift Position (CAN) Undefined/P range/Not P range
350 Vehicle Request Shift Position (LIN) Undefined/P range/Not P range
360 Vehicle Request Shift Position Undefined/P range/Not P range
370 Request Shift Position Undefined/P range/Not P range
380 Motor Control Mode Initial wait/Initial actuation/Normal control/P side wall detection/P side wall return/Not P side wall detection/Not P side wall return/Fail-safe control
390 Motor Drive Mode Standby/Stop/Retention at inversion/Feedback actuation/Energizing phase learning/Open actuation
400 Current Shift Position Counter The number of times is displayed.
410 Target Shift Position Counter The number of times is displayed.
430 P Position Learned Value The number of times is displayed.
440 Not P Position Learned Value The number of times is displayed.
470 Current Shift Position Undefined/P range/Intermediate range/Not P range
510 ACT Control Monitor Failure Normal/Failure
520 Redundancy Calculation Failure Normal/Failure
530 Range Position Signal Failure Normal/Failure
540 Micro Computer Failure (Energization cut) Normal/Failure
550 Micro Computer Failure (CPU diag monitor) Normal/Failure
560 CAN Lost Failure (PHEV_OUT_1) Normal/Failure
570 CAN Lost Failure (PHEV_OUT_14) Normal/Failure
580 CAN Lost Failure (PHEV_OUT_13) Normal/Failure
590 CAN Lost Failure (PHEV_OUT_2) Normal/Failure
600 CAN Lost Failure (PHEV_OUT_16) Normal/Failure
610 CAN Lost Failure (PHEV_OUT_19) Normal/Failure
620 CAN DLC Failure (PHEV_OUT_1) Normal/Failure
630 CAN DLC Failure (PHEV_OUT_14) Normal/Failure
640 CAN DLC Failure (PHEV_OUT_13) Normal/Failure
650 CAN DLC Failure (PHEV_OUT_2) Normal/Failure
660 CAN DLC Failure (PHEV_OUT_16) Normal/Failure
670 CAN DLC Failure (PHEV_OUT_19) Normal/Failure
680 P position request (CAN) No request/Request
690 Not P position request (CAN) No request/Request
700 GADE_v2 Sleep or Crank fault/Auto ACC fault/ALL fault/ALLfault 2/FOTA switch fault/Unavailable
710 EV ePark lost (CAN) Normal/Failure
720 IG signal (CAN) IG-OFF/IG-ON
730 Battery Voltage V
740 CAN send data failure status Unavailable/Abnormal (temporary)/Abnormal/Normal
750 Motor Drive Mode_LV2 Standby/Stop/Open drive
760 Vehicle Current Shift Position Not learning/P range/Not P range/Switching/Default
770 ASIC Failure Flag Normal/Failure
780 ASIC Logic Diag Failure Flag Normal/Failure
790 ASIC Comm Failure Detection Status Normal/Failure
800 ASIC Comm Failure Flag Normal/Failure
810 ASIC Monitor Failure Detection Not monitored/Monitor condition fail/Config monitorfailure/Lost monitor failure/Pattern monitor failure/IDmonitor failure/Counter monitor failure/Disable monitorfailure/Relay cut monitor failure/Monitorperformed/Monitor skip
820 ASIC Monitor Complete Flag OFF/ON
830 CAN CRC Error (PHEV_OUT_1) Normal/Failure
840 CAN Counter Error (PHEV_OUT_1) Normal/Failure
850 KEY for CAN Sending A value (0 to 65535) is displayed.
860 CPU Failure Detection Status OFF/ON
870 Response Error Flag (LIN) Normal/Failure
880 LIN TimeOut Timer (EV_OUT_1) ms
890 LIN TimeOut Timer (EV_OUT_DIAG) ms
900 LIN TimeOut Timer (E_PARK_OUT) ms