Check Hydraulic Solenoids
With ignition switch in OFF position, connect breakout box with adapter to ABS control module connector. Leave ABS control module disconnected. Measure resistance between breakout box pins No. 6 and 51, No. 6 and 32, and No. 6 and 8. If resistances are between 1 and 3 ohms, replace ABS control module. If resistances are not between 1 and 3 ohms, go to PINPOINT TEST D14 .