Main Relay Operation Inspection
- Verify that the main relay clicks when the ignition switch is turned to ON position and then off.
- If there is no operation sound, inspect the following:
- Main relay (See RELAY INSPECTION [L3 WITH TC] .)
- Wiring harness and connector between ignition switch and main relay terminal 5.
- Wiring harness and connector between PCM terminal 1AT and main relay terminal 2.
- If there is no operation sound, inspect the following: