Resistance Inspection
NOTE:
- Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. (See HOW TO USE THIS MANUAL .)
- Disconnect MAP/boost air temperature sensor.
- Measure the resistance between the MAP/boost air temperature sensor terminals A and B using a tester.
- If not as specified, replace the MAP/boost air temperature sensor. (See MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR/BOOST AIR TEMPERATURE SENSOR REMOVAL/INSTALLATION .)
- If the MAP/boost air temperature sensor is normal, but PID are out of specification, perform the "Circuit Open/Short Inspection".
SPECIFICATION
| Ambient temperature (°C {°F}) | Resistance (kilohm) |
|---|---|
| 20 {68} | 2.4-2.7 |
| 60 {140} | 0.59-0.64 |