Instrument Panel Speaker: Inspection
- INSPECT FRONT NO. 2 SPEAKER ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1-2 Always Approx. 6 Ω *1 1-2 Always 5 to 7 Ω *2 HINT: - *1: for Standard models.
- *2: for 19 speakers models.
If the result is not as specified, replace the speaker assembly.
- Measure the resistance according to the value(s) in the table below.
- INSPECT FRONT NO. 3 SPEAKER ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1-2 Always Approx. 6 Ω *1 1-2 Always 5 to 7 Ω *2 HINT: - *1: for standard models.
- *2: for 19 speakers models.
If the result is not as specified, replace the speaker assembly.
- Measure the resistance according to the value(s) in the table below.