  1. CHECK ACTUATOR 
    1. Turn the ignition switch ON while pressing the A/C control AUTO switch and Recirculation / Fresh (R/F) select switch simultaneously.
      Fig 1: Locating A/C Control Auto Switch And Recirculation / Fresh (R/F) Select Switch
      G05291853Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. After entering the DTC check mode (Sensor Check Mode), press the R/F select switch.
    3. Each damper, motor and relay will automatically operate the actuator check at 1 second intervals from step No. 1 to No. 10 (see table below). At this time, check the temperature on the display and check the air flow with your hand.

      If a slower display speed is desired, press the temperature up switch to change the "step no." display. Each press of the switch will change the step no. by  1.

      Fig 2: Locating R/F Select Switch
      G05291854Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      • Codes are displayed as numbers from lowest to highest.
      • To cancel the check mode, press the OFF switch.
      DISPLAY CODE CHART

      Step No. Display Code Conditions
      Blower Level Air Flow Vent Air Inlet Damper Magnet Clutch Air Mix Damper Lap-jet Damper
      1 0 0 FACE FRESH OFF COOL Side (Fully closed) CLOSE
      2 1 1 FACE FRESH OFF COOL Side (Fully closed) CLOSE
      3 2 14 FACE RECIRCULATION/FRESH OFF COOL Side (Fully closed) CLOSE
      4 3 14 FACE RECIRCULATION/FRESH ON COOL Side (Fully closed) CLOSE
      5 4 14 FACE RECIRCULATION ON COOL / WARM (50% open) CLOSE
      6 5 14 BI-LEVEL RECIRCULATION ON COOL/ WARM (50% open) CLOSE
      7 6 14 FOOT/DEF RECIRCULATION ON WARM side (Fully opened) CLOSE
      8 7 14 FOOT RECIRCULATION ON WARM side (Fully opened) OPEN
      9 8 14 FOOT/DEF RECIRCULATION ON WARM side (Fully opened) OPEN
      10 9 31 DEF RECIRCULATION ON WARM side (Fully opened) CLOSE