LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2008 >> GS 450h >> Repair and Diagnosis >> Suspension >> Suspension Control Systems >> Suspension Control >> Active Stabilizer Suspension System >> Data List / Active Test

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using the Techstream's DATA LIST allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the DATA LIST early in troubleshooting is one way to save time.

    1. Turn the power switch OFF.
    2. Connect Techstream to the DLC3.
    3. Turn the power switch ON (IG) and turn the tester ON.
    4. Check the values by referring to the table below.

      Active stabilizer control ECU 

      NORMAL CONDITION CHART

      Tester Display Measurement Item/ Range Normal Condition Reference Value Diagnostic Note
      Vehicle Speed Vehicle speed/ Min.: 0 km/h (0 mph) Max.: 300 km/h (187 mph) Vehicle is stopped 0 km/h -
      Vehicle is driven at constant speed Value does not vary significantly -
      FR Wheel Speed Front RH wheel speed/ Min.: 0 km/h (0 mph) Max.: 655.35 km/h (409.5 mph) Vehicle is stopped 0 km/h -
      Vehicle is driven at constant speed Value does not vary significantly -
      FL Wheel Speed Front LH wheel speed/ Min.: 0 km/h (0 mph) Max.: 655.35 km/h (409.5 mph) Vehicle is stopped 0 km/h -
      Vehicle is driven at constant speed Value does not vary significantly -
      RR Wheel Speed Rear RH wheel speed/ Min.: 0 km/h (0 mph) Max.: 655.35 km/h (409.5 mph) Vehicle is stopped 0 km/h -
      Vehicle is driven at constant speed Value does not vary significantly -
      RL Wheel Speed Rear LH wheel speed/ Min.: 0 km/h (0 mph) Max.: 655.35 km/h (409.5 mph) Vehicle is stopped 0 km/h -
      Vehicle is driven at constant speed Value does not vary significantly -
      IG Power Supply ECU power voltage condition (IG)/ Min.: 0 V Max.: 19.979 V Power switch ON (IG) 10 to 14 V -
      PIG Power Supply ECU power voltage condition (PIG)/ Min.: 0 V Max.: 19.979 V Power switch ON (IG) 10 to 14 V -
      Steering Angle Steering angle (turning to left is positive)/ Min.: -3072° Max.: 3070.5° Move steering wheel to neutral point Close to 0 -
      Rotate steering wheel Continuously varies -
      Yaw Rate Sensor 1 Yaw rate value/ Min.:-1.7425°red/s Max.: 1.73825°red/s Vehicle is stopped 0°red/s -
      Vehicle is turned 0 to-1.7425°red/s -
      Vehicle is turned 0 to 1.73825° red/s -
      Yaw Rate Sensor 2 Yaw rate value/ Min.: -1.7425°red/s Max.: 1.73825°red/s Vehicle is stopped 0°red/s -
      Vehicle is turned 0 to -1.7425° red/s -
      Vehicle is turned 0 to 1.73825° red/s -
      Right And Left G Right and left G/ Min.:-321.45408 m/s2 Max.: 321.44427 m/s2 Vehicle is accelerated or decelerated Continuously varies -
      Back And Forth G Front and rear G/ Min.: -321.45408 m/s2 Max.: 321.44427 m/s2 Vehicle is accelerated or decelerated Continuously varies -
      Engine Speed Engine rpm/ Min.: 0 rpm Max.: 12800 rpm Vehicle is stopped 0 rpm -
      Engine is running at constant speed Value does not vary significantly -
      Fr Twist Angle Front stabilizer twist angle/ Min.: -2457.6° Max.: 2457.525° Vehicle is stopped on level surface Approximately 0 -
      During roll control Continuously varies -
      Rr Twist Angle Rear stabilizer twist angle/ Min.: -2457.6° Max.: 2457.525° Vehicle is stopped on level surface Approximately 0 -
      During roll control Continuously varies -
      Fr Target Torq Front control target torque value/ Min.: -3276.8 N*m Max.: 3276.7 N*m - - -
      Rr Target Torq Rear control target torque value/ Min.: -3276.8 N*m Max.: 3276.7 N*m - - -
      Number of DTC Number of diagnosis codes Min.: 0 Max.: 255 - Displays DTCs being output -