LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2006 >> GX 470 >> Repair and Diagnosis >> External Pages >> Different car >> Section 95 (Lighting) >> Lighting System >> DRL Relay Circuit >> Inspection Procedure

Inspection Procedure

WARNING: This page is about a different car, the 2007 Lexus GX 470. However, it is still accessible from the selected car via links, so may be relevant.
  1. PERFORM ACTIVE TEST BY INTELLIGENT TESTER 
    1. Connect the intelligent tester to DLC3.
    2. Turn the ignition switch ON and push the intelligent tester main switch ON.
    3. Select the item below in the ACTIVE TEST and then check that the relay operates.

    Body: 

    ACTIVE TEST TABLE

    Item Test Details Diagnostic Note
    DRL RLY (Test Details)
    Turns DRL relay in the turn signal flasher ON/OFF
    (Vehicle Condition)
    IG switch is ON, Engine is stopped and light control switch is in OFF position.
    -

    OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

    NG: Go to next step. 

  2. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (DRL) 
    Fig 1: Identifying Instrument Panel Junction Block Assembly Connector Terminals (DRL)
    G05265724Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the connector.
    2. Measure the voltage between terminal DRL of the instrument panel J/B assembly (driver side J/B assembly) and body ground on the wire harness side.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester connection Condition Specified condition
      B3-7 (DRL) - Ground Engine is running 10 to 14 V

    OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE 

    NG: Go to next step. 

  3. INSPECT TURN SIGNAL FLASHER ASSEMBLY 
    Fig 2: Identifying Turn Signal Flasher Assembly Connector Terminals
    G05265736Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the connector.
    2. Measure the voltage between terminals on the wire harness side as shown in the table below.

    Standard voltage 

    TESTER CONNECTION SPECIFIED CONDITION TABLE

    Tester connection Condition Specified condition
    9 (E) - Ground Always Continuity
    1 (IG) - Ground Turn ignition switch ON Battery positive voltage
    1 (IG) - Ground Turn ignition switch OFF No voltage
    6 (B) - Ground Always Battery positive voltage

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step. 

  4. INSPECT TURN SIGNAL FLASHER ASSEMBLY 
    Fig 3: Identifying Turn Signal Flasher Assembly Connector Terminal
    G05265737Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Connect the connector to the turn signal flasher and turn the ignition switch to ON, and inspect the wire harness side connector on the back side as shown in the table.

    Standard voltage 

    TESTER CONNECTION SPECIFIED CONDITION TABLE

    Tester connection Condition Specified condition
    12 (DRL) - Ground Turn ignition switch ON and engine OFF → ON 10 to 14 V → 0 V

    NG: REPLACE TURN SIGNAL FLASHER ASSEMBLY 

    OK: REPAIR OR REPLACE HARNESS OR CONNECTOR