LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2004 >> RX 330 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 583 (Air Conditioning) >> Air Conditioning System >> Customize Parameters

Customize Parameters

WARNING: This page is about a different car, the 2008 Lexus RX 350. However, it is still accessible from the selected car via links, so may be relevant.

HINT:

The followings are the possible items to be customized.

NOTE:
  • After confirming whether the items of the customer's request is applicable or not for the customized items, perform the customize operation.
  • Be sure to record the current value before customizing.
  • In case of performing the troubleshooting, pay attention as there is a possibility that the function is OFF by customizing. (Example: In case of the symptom in which "The wireless operation does not function", check that the wireless operation is not OFF by customizing, then perform the troubleshooting.)

AIR CONDITIONER: 

AIR CONDITIONER REFERENCE CHART

DISPLAY (ITEM) DEFAULT CONTENTS SETTING
SET TEMP SHIFT (Set Temperature Shift) NORMAL To control with the shifted temperature against the display temperature. +2C / +1C / NORMAL / -1C / -2C
AIR INLET MODE (Air Inlet Mode) AUTO In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATED mode. AUTO/MANUAL
COMPRESSOR MODE (Compressor Mode) AUTO Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF. AUTO / MANUAL
COMPRS/DEF OPER (Compressor/Air inlet DEF operation) LINK Function to turn the A/C ON automatically linking with the FRONT DEF button when the A/C OFF. LINK/NORMAL
BUTTON PRS BUZ (Button press buzzer) ON Function to sound a buzzer when button is pressed. OFF / ON
FOOT/DEF MODE (Foot/DEF auto mode) ON Function to turn the air flow from FOOT/DEF ON automatically when AUTO MODE is ON. ON / OFF
AIR CONDITIONER REFERENCE CHART

AMBINT TMP SFT (Ambient Temperature Shift) NORMAL To control with the shifted ambient temperature against the display ambient temperature. +3C / +2C / +1C / NORMAL / -1C / -2C / -3C