Verification Of Repair
After a repair, it is essential to verify that the fault has been corrected.
- Connect KDS to Data Link Connector (DLC), and monitor "Diagnostic".
- Clear all DTCs in the system with KDS.
- Operate system or vehicle within DTC detecting condition in DTC detecting condition chart.
- Monitor "Diagnostic Trouble Codes (DTC)" with KDS and verify that any DTC is stored.
- Verify that the DTC is cleared and system operates correctly.
* When inspecting and replacing high-voltage related components, perform "Actuation Test → Vehicle Control Unit → Battery EWP Operation Mode for Degassing and Circulation".
Good
- Problem is corrected and the system operation performs to specification at this time.
No Good
- Go to applicable troubleshooting procedure.