Repair Procedures: Inspection: Compressor
WARNING: This page is about a different variant/trim than selected.
RPM check
- Push the A/C control switch ON.
- Check the engine RPM.CAUTION: When the compressor operates, RPM increases.
- When the compressor is operating, RPM should be as follows.
PART SPECIFICATION (NU 2.0 MPI)
| Item | Specification | ||
|---|---|---|---|
| Idle Speed (rpm) | A/C OFF | Neutral, N, P-range | 660 ± 100 |
| D-range | 660 ± 100 | ||
| A/C ON | Neutral, N, P-range | 660 ± 100 | |
| D-range | 660 ± 100 | ||
PART SPECIFICATION (NU 2.0 CVVL)
| Item | Specification | |||
|---|---|---|---|---|
| Idle Speed (rpm) | A/T | A/C OFF | Neutral, D, N, P-range | 660 ± 100 |
| A/C ON | Neutral, D, N, P-range | 600 ± 100 | ||
| M/T | A/C OFF | 660 ± 100 | ||
| A/C ON | 660 ± 100 | |||
PART SPECIFICATION (THETA-II 2.4 GDI)
| Item | Specification | ||
|---|---|---|---|
| Idle Speed (rpm) | A/C OFF | Neutral, N, P-range | 640±100 |
| D-range | 600±100 | ||
| A/C OFF | Neutral, N, P-range | 660 ± 100 | |
| D-range | 660 ± 100 | ||
PART SPECIFICATION (THETA-II 2.0 T-GDI)
| Item | Specification | ||
|---|---|---|---|
| Idle Speed (rpm) | A/C OFF | Neutral, N, P-range | 640 ± 100 |
| D-range | 600 ± 100 | ||
| A/C OFF | Neutral, N, P-range | 660 ± 100 | |
| D-range | 660 ± 100 | ||
PART SPECIFICATION (THETA 2.4 MPI)
| Item | Specification | ||
|---|---|---|---|
| Idle Speed (rpm) | A/C OFF | Neutral, N, P-range | 680±100 |
| D-range | 620±100 | ||
| A/C OFF | Neutral, N, P-range | 680 ± 100 | |
| D-range | 650±100 | ||
PART SPECIFICATION (U-II 1.7 TCI)
| Item | Specification | ||
|---|---|---|---|
| Idle Speed (rpm) | A/C OFF | Neutral, N, P-range | 790±100 |
| 1-range creep | 790±100 | ||
| A/C OFF | Neutral, N, P-range | 790 ± 100 | |
| 1-range creep | 790 ± 100 | ||