Repair Procedures: Inspection
- Ignition "OFF"
- Disconnect the connector of mode control actuator.
- Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 4.
- Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
- Check the voltage between terminals 6 and 7.VOLTAGE SPECIFICATION
Door position Voltage (6-7) Error detecting Vent 0.3 ± 0.15V Low voltage: 0.1V or less Defrost 4.7 ± 0.15V High voltage: 4.9V or more * It will feedback current position of actuator to controls.
- If the measured voltage is not specification, substitute with a known-good console temp control actuator and check for proper operation.
- If the problem is corrected, replace the console temp control actuator.