DTC Description
This diagnostic monitors the phasing response rate and determines whether the response rate is fast enough. A state machine is used to capture the response rate. The measured results are then compared to an allowable threshold. If "Counter of < Δ (original target - actual angle) < 3 Deg" is over 10 times under enable conditions, PCM sets DTC P0011.