Cooling System: Inspection: Thermostat
- Immerse the thermostat in water and gradually heat the water.
- Check the valve opening temperature.
Valve opening temperature: 82±1.5°C (179.6±2.7°F)
Full opening temperature: 95°C (203°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift: 8mm (0.3in) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.