Operation Inspection
WARNING: This page is about a different car, the 2018 Infiniti Q60. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK PLASMACLUSTER ™
CONTROL
Check the ionizer operation sound (whirring sound) in the duct by putting an ear to the center ventilator grille (driver side) outlet while pressing fan switch and OFF switch alternately.
Is the inspection result normal?
YES
GO TO 2.
NO
GO TO 4.
- CHECK PLASMACLUSTER ™
CONTROL OPERATION STATUS
Operate fan switch. Visually check that status indicator in lower touch screen display changes in accordance with the following table.
Fan speed
Lower touch screen display (ion indicator)
1st - 3rd
CLEAN
4th - 7th
QUICK CLEAN
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 4.
- CHECK AUTOMATIC INTAKE CONTROL (EXHAUST GAS/OUTSIDE ODOR DETECTING MECHANISM)
- Operate fan switch to set the fan speed to maximum speed.
- Touch auto intake switch to set the air inlet to recirculation. The auto intake switch indicator and intake switch indicator lamp turn ON.
- Listen to intake sound and confirm air inlets change.
- Wait approximately for 5 minutes until air inlet switches to fresh air intake.
- Apply cigarette smoke or similar substance to exhaust gas/outside odor detecting sensor portion.
- Listen to intake sound and confirm air inlets change to recirculation.
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 4.
- CHECK SELF-DIAGNOSIS WITH CONSULT
- Perform self-diagnosis with CONSULT.
- Check that any DTC is detected.
Is any DTC detected?
YES
Refer to DTC Index and perform the appropriate diagnosis.
NO
Refer to Symptom Table and perform the appropriate diagnosis.