Check Intelligent Key Unit Power Supply and Ground Circuit
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition knob OFF position.
- Disconnect Intelligent Key unit connector.
- Check voltage between Intelligent Key unit connector and ground.VOLTAGE SPECIFICATIONS
Connector Terminal (Wire color) Ignition knob position M34 (+) (-) OFF ACC ON 6 (W) Ground 0V 0V Battery voltage 10 (LG) 0V Battery voltage Battery voltage 11 (L/R) Battery voltage Battery voltage Battery voltage
OK or NG
OK : GO TO 2.
NG : Repair or replace Intelligent Key power supply circuit.
- CHECK GROUND CIRCUIT
Check continuity between Intelligent Key unit connector M34 terminal 12 (B) and ground.
12 (B) - Ground : Continuity should exist.
OK or NG
OK : Power supply and ground circuits are normal.
NG : Repair or replace the Intelligent Key unit ground circuit.