RECIRCULATION Control Switch
Remove heater control panel. Check for continuity between specified terminals of heater control panel connector. See RECIRCULATION CONTROL SWITCH TEST table. See Figure. If continuity does not exist, replace heater control panel.
RECIRCULATION CONTROL SWITCH TEST
| Switch Position | Continuity Should Exist Between Terminals No. |
|---|---|
| Fresh | 11 & 2 |
| Recirculation | 4 & 2 |