Purge Solenoid Valve
Solenoid valve is controlled by Electronic Control Module (ECM). When energized, purge solenoid valve turns off causing vapors to be drawn from canister through restriction and allowing high purge.
For high purge to occur, following conditions must be met: fuel control system must be operating in closed loop, time of 3 minutes must pass after starting engine, and engine must be off idle.