Component testing procedure
MASTER WINDOW/DOOR LOCK/UNLOCK SWITCH - COMPONENT TESTING
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Power and Ground Checks Before Any Other Tests | 11 and 10 11 and 14 3 and 2 3 and 6 |
All window switches at rest | Open circuit |
| 2 and 1 6 and 7 10 and 9 14 and 15 |
All window switches at rest | Closed circuit | |
| Left front window circuit | 11 and 15 | Up | Closed circuit |
| 11 and 9 | Down | Closed circuit | |
| Right front window circuit | 3 and 7 | Up | Closed circuit |
| 3 and 1 | Down | Closed circuit |