LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1999 >> Cutaway E250 >> Repair and Diagnosis >> Electrical >> Body Electrical >> Module Communications Network >> Self-Diagnostic System >> Accessing Parameter Identification (PID)

Accessing Parameter Identification (PID)

Turn ignition switch to LOCK position. Connect New Generation Star (NGS) tester to Data Link Connector (DLC). Following manufacturers instructions enter PID/DATA MONITOR AND RECORD for desired module. Operate appropriate system and ensure PID expected values are obtained. See appropriate table under PARAMETER IDENTIFICATION (PID) DEFINITIONS .