Continuity Check
Turn ignition off. Disconnect VAPS module from harness connector. Disconnect actuator from harness connector. Check for continuity in circuit No. 495 between module and actuator harness connectors. See Figure . Check for continuity in circuits No. 496, 497 and 498 between module and actuator harness connectors. If all circuits check okay, go to PINPOINT TEST A9 . Repair any circuit that does not show continuity, and go to PINPOINT TEST A2 .