Code 3 (Open Dump Circuit)
- Turn ignition off. Disconnect battery. Unplug control module connector. Measure resistance between pin No. 8 or 14 and ground on valve side. See Figure . If resistance is less than 3 ohms, replace control module. If resistance is 3 ohms or more, reconnect module connector.
- Unplug electro-hydraulic valve connector. Measure resistance between dump solenoid pin and ground pin on valve side. If resistance is less than 3 ohms, repair open between dump valve connector and control module. If resistance is 3 ohms or more, replace electro-hydraulic valve.