Computed Ignition Timing Check
This checks the system's ability to correctly change and maintian spark timing. Ignition timing will be advanced 20° from base timing. Timing will be locked in through Self-Test and during 2 minute period after end of Self-Test outs.
NOTE:
If engine will not start, go to Circuit TEST A
. If engine stalls while testing, go to Diagnosis By Symptom TEST which can be found in specific engine section.
Make sure that in-line base timing connector is reconnected if base timing has been checked. Make sure that Self-Test is activated and start engine. Timing is locked for full Self-Test sequence and for 2 minutes after display of last service code. Timing range should be 27-33° BTDC on all models. If timing is correct, go to Engine Running Self-Test. If timing is not correct, go to TEST MM .
NOTE:
If engine will not start, go to TEST A
. If engine stalls while testing, go to Diagnosis By Symptom Test.