Installation Procedure
- Install Battery Energy Control Module (2)
- Disconnect ALL of the battery energy control module connectors prior to disconnecting any Hybrid/EV battery section connector.
- Reconnect all the Hybrid/EV battery section connectors prior to reconnecting the battery energy control module connectors.
- Disconnect and reconnect the battery energy control module connectors ONLY in the sequence provided in Repair Instructions.
- Connect the battery energy control module connectors in the sequence shown above.
- Connect the battery energy control module connectors in the sequence shown above.
- Install High Voltage Battery Cover. Refer to High Voltage Battery Cover Replacement
- Install Drive Motor Battery. Refer to Drive Motor Battery Replacement and Shipping Preparation
- Program the battery energy control module. Refer to Control Module References
CAUTION:
The battery energy control modules internal cell balancing circuitry is powered by the cell group voltage sense circuits. In order to prevent an unrecoverable, unbalanced Hybrid/EV battery section or internal control module damage, always take the following actions:
NOTE:
Service replacement module requires programming.