Test Conditions
- MAP value not varying by more than 10 kPa at steady state operation.
- MAT value greater than 30°C.
- Coolant temperature 40°C or greater.
- Battery voltage 11 or greater volts.
- Engine RPM:
- Between 1200 and 1225 RPM or;
- Between 3600 and 5100 RPM.
- Engine running for at least 2 seconds.