System Operational Test
- Unload vehicle. With ignition off, check riding height. Turn ignition on. Add 300-350 lbs. (136-159 kg) load to trunk. Compressor should start operating within approximately 7-10 seconds. Vehicle should rise to within 3/4" (19 mm) of riding height.
- Remove load from trunk. Exhaust should start within approximately 7-10 seconds. Within 2 minutes, exhaust should stop and vehicle should be within 3/4" (19 mm) of riding height.