System Check
NOTE:
In text, master switch refers to left hand front window switch (4 Door) or left hand master switch assembly (2 Door).
- Operate each window UP and DN from the master switch. Each window should operate quietly and smoothly, without sticking.
- Operate each window from its individual window switch. Each window should operate quietly and smoothly, without sticking.
- Momentarily press left hand front switch DN past the first detent. Window should continue to fully down position.
- Lock out switch in LOCK position (4 Door), windows should operate from left hand master switch assembly and not from their individual switches.
- Lock out switch in OFF position (4 Door), all windows should operate normally from their individual switches.
- If any of the above steps are not as specified, see SYMPTOM DIAGNOSIS in this article.