Distribution of Hydraulic Pressure

As the engine turns, the ATF pump starts to operate Automatic transmission fluid (ATF) is drawn through the ATF strainer (filter) and discharged into the hydraulic circuit Then, ATF flowing from the ATF pump becomes line pressure that is regulated by the regulator valve Torque converter pressure from the regulator valve enters the torque converter through the lock-up shift valve and lock-up control valve, and it is discharged from the torque converter The torque converter check valve prevents torque converter pressure from rising

The PCM switches shift solenoid valves ON and OFF, and the shift solenoid valves control shift solenoid pressure to the shift valves Applying shift solenoid pressure to the shift valves moves the position of the shift valve, and switches the port of hydraulic pressure The PCM also controls A/T clutch pressure control solenoid valves A, B, and C The A/T clutch pressure control solenoid valves regulate hydraulic pressure, and applies the pressure to CPC valves A, B, and C

When shifting between gears, the clutches are engaged by pressure from the CPC pressure mode The PCM actuates one of the shift solenoid valves to move the position of the shift valve This movement switches the port of CPC pressure and line pressure Line pressure is then applied to the clutch, and CPC pressure is released The clutch is engaged with line pressure after shifting is completed

Hydraulic Pressure at the Port for use in the hydraulic circuit 

HYDRAULIC PRESSURE SPECIFICATION

Port No Hydraulic Pressure
1 Line
2 Line
3 Line
3' Line
3" Reverse CPC or Line
3A Line
3B Reverse CPC
4 Line
4' Line
4" Line
4A CPC A
4B CPC B
4C CPC C
5A CPC A
5B CPC A or Line
5C CPC B or Line
5D CPC B
5E CPC C
5F CPC C
5G CPC C
5H CPC B or Line
5J CPC B or Line
5K CPC A or Line
5L CPC A or Line
5M Line
5N CPC C
6 Modulator
SA Shift solenoid valve A
SB Shift solenoid valve B
SC Shift solenoid valve C
SD Shift solenoid valve D
10 1st clutch
15 1st-hold clutch
20 2nd clutch
30 3rd clutch
40 4th clutch
50 5th clutch
51 5th clutch
56 A/T clutch pressure control solenoid valve A
57 A/T clutch pressure control solenoid valve B
5R A/T clutch pressure control solenoid valve B
58 A/T clutch pressure control solenoid valve C
90 Torque converter
90' Torque converter
91 Torque converter
91' Torque converter
92 Torque converter
93 ATF cooler
94 Torque converter
95 Lubrication
95' Lubrication
96 Torque converter
99 Suction
X Drain
HX High position drain
AX Air dam
- -